Paired Flat Silicone-rubber Insulated/Glass-Braid Sheathed Extension and Compensating Cables for Thermocouples

We provide paired flat extension and compensating cables for thermocouples, consisting of a pair of conductors individually silicone-rubber insulated, and then glass-braid sheathed. As required, wires can be optionally shielded (to eliminate electrostatic induction interference) and/or protectively braided (to protect the wire surface from damage).

  • Shield type
    IS: Tinned-annealed-copper-wire braided shield TIS: Copper-tape shield AIS: Aluminum-polyester-tape shield containing drain wire
  • Protective braid type
    SOS: Protective stainless-wire braid OS: Protective tinned-annealed-copper-wire braid
Nominal cross-sectional area Type Cross Section Conductor Insulation Pair Shield Protective braid Sheath Standard Max length Estimated weight
Composition Outside diameter Thickness Outside diameter Outside diameter Outside diameter Thickness Thickness Outside diameter
mm2 Pcs/mm mm mm mm mm mm mm mm mm m kg/km
0.3 12/0.18 x1P
□-SRGB-◇
1 12/0.18 0.7 0.35 1.4 1.4×2.8 0.3 2.0×3.4 1,000 13
0.3 12/0.18 x1P
□-SRGB-◇-IS
2 12/0.18 0.7 0.35 1.4 1.4×2.8 0.3 0.3 2.6×4.0 1,000 23
0.3 12/0.18 x1P
□-SRGB-◇-SOS
3 12/0.18 0.7 0.35 1.4 1.4×2.8 0.3 0.3 2.6×4.0 1,000 24
0.5 7/0.3 x1P
□-SRGB-◇
1 7/0.3 0.9 0.5 1.9 1.9×3.8 0.3 2.5×4.4 1,000 20
0.5 7/0.3 x1P
□-SRGB-◇-IS
2 7/0.3 0.9 0.5 1.9 1.9×3.8 0.3 0.3 3.1×5.0 1,000 33
0.5 7/0.3 x1P
□-SRGB-◇-SOS
3 7/0.3 0.9 0.5 1.9 1.9×3.8 0.3 0.3 3.1×5.0 1,000 34
0.5 20/0.18 x1P
□-SRGB-◇
1 20/0.18 1.0 0.45 1.9 1.9×3.8 0.3 2.5×4.4 1,000 20
0.5 20/0.18 x1P
□-SRGB-◇-IS
2 20/0.18 1.0 0.45 1.9 1.9×3.8 0.3 0.3 3.1×5.0 1,000 32
0.5 20/0.18 x1P
□-SRGB-◇-SOS
3 20/0.18 1.0 0.45 1.9 1.9×3.8 0.3 0.3 3.1×5.0 1,000 32
0.75 30/0.18 x1P
□-SRGB-◇
1 30/0.18 1.2 0.5 2.2 2.2×4.4 0.3 2.8×5.0 1,000 27
0.75 30/0.18 x1P
□-SRGB-◇-IS
2 30/0.18 1.2 0.5 2.2 2.2×4.4 0.3 0.3 3.4×5.6 1,000 41
0.75 30/0.18 x1P
□-SRGB-◇-SOS
3 30/0.18 1.2 0.5 2.2 2.2×4.4 0.3 0.3 3.4×5.6 1,000 42
1.25 7/0.45 x1P
□-SRGB-◇
1 7/0.45 1.35 0.6 2.55 2.55×5.1 0.35 3.3×5.8 1,000 39
1.25 7/0.45 x1P
□-SRGB-◇-IS
2 7/0.45 1.35 0.6 2.55 2.55×5.1 0.3 0.35 3.9×6.4 1,000 56
1.25 7/0.45 x1P
□-SRGB-◇-SOS
3 7/0.45 1.35 0.6 2.55 2.55×5.1 0.35 0.3 3.9×6.4 1,000 57
1.25 50/0.18 x1P
□-SRGB-◇
1 50/0.18 1.5 0.5 2.5 2.5×5.0 0.35 3.2×5.7 1,000 41
1.25 50/0.18 x1P
□-SRGB-◇-IS
2 50/0.18 1.5 0.5 2.5 2.5×5.0 0.3 0.35 3.8×6.3 1,000 58
1.25 50/0.18 x1P
□-SRGB-◇-SOS
3 50/0.18 1.5 0.5 2.5 2.5×5.0 0.35 0.3 3.8×6.3 1,000 59
1.3 4/0.65 x1P
□-SRGB-◇
1 4/0.65 1.57 0.6 2.77 2.77×5.54 0.35 3.5×6.2 1,000 44
1.3 4/0.65 x1P
□-SRGB-◇-IS
2 4/0.65 1.57 0.6 2.77 2.77×5.54 0.3 0.35 4.1×6.8 1,000 60
1.3 4/0.65 x1P
□-SRGB-◇-SOS
3 4/0.65 1.57 0.6 2.77 2.77×5.54 0.35 0.3 4.1×6.8 1,000 62
2.3 7/0.65 x1P
□-SRGB-◇
1 7/0.65 1.95 0.6 3.15 3.15×6.3 0.35 3.9×7.0 1,000 68
2.3 7/0.65 x1P
□-SRGB-◇-IS
2 7/0.65 1.95 0.6 3.15 3.15×6.3 0.3 0.35 4.5×7.6 1,000 85
2.3 7/0.65 x1P
□-SRGB-◇-SOS
3 7/0.65 1.95 0.6 3.15 3.15×6.3 0.35 0.3 4.5×7.6 1,000 86
When placing an order, please replace each of the □ symbols with the type and tolerance class of the appropriate extension and compensating cable for thermocouples (see Table 1), and each of the ◇ symbols with its identification code (see Table 2).

In addition to paired cables, we can make multi-pair cables. Please consult us.
The estimated weights represent calculated values for reference purposes, which do not include the weight of the drum.
*Please feel free to contact our Sales Department for custom-made products not listed above.