Max. operating temp:200℃
Paired Round FEP Insulated/FEP Sheathed Extension and Compensating Cables for Thermocouples
We provide paired round extension and compensating cables for thermocouples, consisting of a pair of conductors individually insulated with FEP, a fluorine resin, twisted together with an inclusion, and then sheathed with FEP. As required, wire can be optionally shielded (to eliminate electrostatic induction interference) and/or protectively braided (to protect the wire surface from damage).
- Shield type
IS: Tinned-annealed-copper-wire braided shield TIS: Copper-tape shield AIS: Aluminum-polyester-tape shield containing drain wire - Protective braid type
SOS: Protective stainless-wire braid OS: Protective tinned-annealed-copper-wire braid
Nominal cross-sectional area | Type | Cross Section | Conductor | Insulation | Pair | Shield | Protective braid | Sheath | Standard | Max length | Estimated weight | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Composition | Outside diameter | Thickness | Outside diameter | Outside diameter | Outside diameter | Thickness | Thickness | Outside diameter | |||||
mm2 | Pcs/mm | mm | mm | mm | mm | mm | mm | mm | mm | m | kg/km | ||
0.3 | 12/0.18 x1P □-6F-◇=FFR |
1 | 12/0.18 | 0.7 | 0.25 | 1.2 | 2.4 | – | 0.3 | – | 3.1 | 1,000 | 20 |
0.3 | 12/0.18 x1P □-6F-◇-IS=FFR |
2 | 12/0.18 | 0.7 | 0.25 | 1.2 | 2.4 | 0.3 | 0.3 | – | 3.7 | 1,000 | 33 |
0.3 | 12/0.18 x1P □-6F-◇-SOS=FFR |
3 | 12/0.18 | 0.7 | 0.25 | 1.2 | 2.4 | – | 0.3 | 0.3 | 3.7 | 1,000 | 33 |
0.5 | 7/0.3 x1P □-6F-◇=FFR |
1 | 7/0.3 | 0.9 | 0.25 | 1.4 | 2.8 | – | 0.3 | – | 3.5 | 1,000 | 26 |
0.5 | 7/0.3 x1P □-6F-◇-IS=FFR |
2 | 7/0.3 | 0.9 | 0.25 | 1.4 | 2.8 | 0.3 | 0.3 | – | 4.1 | 1,000 | 40 |
0.5 | 7/0.3 x1P □-6F-◇-SOS=FFR |
3 | 7/0.3 | 0.9 | 0.25 | 1.4 | 2.8 | – | 0.3 | 0.3 | 4.1 | 1,000 | 40 |
0.5 | 20/0.18 x1P □-6F-◇ =FFR |
1 | 20/0.18 | 1.0 | 0.25 | 1.5 | 3.0 | – | 0.3 | – | 3.7 | 1,000 | 29 |
0.5 | 20/0.18 x1P □-6F-◇-IS=FFR |
2 | 20/0.18 | 1.0 | 0.25 | 1.5 | 3.0 | 0.3 | 0.3 | – | 4.3 | 1,000 | 43 |
0.5 | 20/0.18 x1P □-6F-◇-SOS=FFR |
3 | 20/0.18 | 1.0 | 0.25 | 1.5 | 3.0 | – | 0.3 | 0.3 | 4.3 | 1,000 | 43 |
0.75 | 30/0.18 x1P □-6F-◇ =FFR |
1 | 30/0.18 | 1.2 | 0.25 | 1.7 | 3.4 | – | 0.35 | – | 4.2 | 1,000 | 39 |
0.75 | 30/0.18 x1P □-6F-◇-IS=FFR |
2 | 30/0.18 | 1.2 | 0.25 | 1.7 | 3.4 | 0.3 | 0.35 | – | 4.8 | 1,000 | 53 |
0.75 | 30/0.18 x1P □-6F-◇-SOS=FFR |
3 | 30/0.18 | 1.2 | 0.25 | 1.7 | 3.4 | – | 0.35 | 0.3 | 4.8 | 1,000 | 53 |
1.25 | 7/0.45 x1P □-6F-◇ =FFR |
1 | 7/0.45 | 1.35 | 0.3 | 1.95 | 3.9 | – | 0.4 | – | 4.8 | 1,000 | 51 |
1.25 | 7/0.45 x1P □-6F-◇-IS=FFR |
2 | 7/0.45 | 1.35 | 0.3 | 1.95 | 3.9 | 0.3 | 0.4 | – | 5.4 | 1,000 | 65 |
1.25 | 7/0.45 x1P □-6F-◇-SOS=FFR |
3 | 7/0.45 | 1.35 | 0.3 | 1.95 | 3.9 | – | 0.4 | 0.3 | 5.4 | 1,000 | 65 |
1.3 | 4/0.65 x1P □-6F-◇=FFR |
1 | 4/0.65 | 1.57 | 0.3 | 2.17 | 4.34 | – | 0.4 | – | 5.2 | 1,000 | 61 |
1.3 | 4/0.65 x1P □-6F-◇-IS=FFR |
2 | 4/0.65 | 1.57 | 0.3 | 2.17 | 4.34 | 0.3 | 0.4 | – | 5.8 | 1,000 | 74 |
1.3 | 4/0.65 x1P □-6F-◇-SOS=FFR |
3 | 4/0.65 | 1.57 | 0.3 | 2.17 | 4.34 | – | 0.4 | 0.3 | 5.8 | 1,000 | 74 |
2.3 | 7/0.65 x1P □-6F-◇=FFR |
1 | 7/0.65 | 1.95 | 0.3 | 2.55 | 5.1 | – | 0.4 | – | 6.0 | 1,000 | 92 |
2.3 | 7/0.65 x1P □-6F-◇-IS=FFR |
2 | 7/0.65 | 1.95 | 0.3 | 2.55 | 5.1 | 0.3 | 0.4 | – | 6.6 | 1,000 | 107 |
2.3 | 7/0.65 x1P □-6F-◇-SOS=FFR |
3 | 7/0.65 | 1.95 | 0.3 | 2.55 | 5.1 | – | 0.4 | 0.3 | 6.6 | 1,000 | 108 |
When placing an order, please replace each of the □ symbols with the type and tolerance class of the appropriate extension and compensating cable for thermocouples (see Table 1), and each of the ◇ symbols with its identification code (see Table 2).
In addition to paired cables, we can make multi-pair cables. Please consult us.
The estimated weights represent calculated values for reference purposes, which do not include the weight of the drum.
*Please feel free to contact our Sales Department for custom-made products not listed above.