Max. operating temp:200℃
Paired Flat FEP Insulated/Glass-Braid Sheathed Extension and Compensating Cables for Thermocouples
We provide paired flat extension and compensating cables for thermocouples, consisting of a pair of conductors individually insulated with FEP, a fluorine resin, and then sheathed with glass braid. As required, wire can be optionally shielded (to eliminate electrostatic induction interference) and/or protectively braided (to protect the wire surface from damage).
- Shield type
IS: Tinned-annealed-copper-wire braided shield - Protective braid type
SOS: Protective stainless-wire braid OS: Protective tinned-annealed-copper-wire braid
Nominal cross-sectional area | Type | Cross Section | Conductor | Insulation | Pair | Shield | Sheath | Standard | Max length | Estimated weight | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Composition | Outside diameter | Thickness | Outside diameter | Outside diameter | Thickness | Thickness | Outside diameter | ||||||
mm2 | Pcs/mm | mm | mm | mm | mm | mm | mm | mm | m | kg/km | |||
0.3 | 12/0.18 x1P □-6FGB-◇ |
1 | 12/0.18 | 0.7 | 0.25 | 1.2 | 1.2×2.4 | – | 0.25 | – | 1.7×2.9 | 1,000 | 12 |
0.3 | 12/0.18 x1P □-6FGB-◇-IS |
2 | 12/0.18 | 0.7 | 0.25 | 1.2 | 1.2×2.4 | 0.3 | 0.25 | – | 2.3×3.5 | 1,000 | 22 |
0.3 | 12/0.18 x1P □-6FGB-◇-SOS |
3 | 12/0.18 | 0.7 | 0.25 | 1.2 | 1.2×2.4 | – | 0.25 | 0.3 | 2.3×3.5 | 1,000 | 22 |
0.5 | 7/0.3 x1P □-6FGB-◇ |
1 | 7/0.3 | 0.9 | 0.25 | 1.4 | 1.4×2.8 | – | 0.25 | – | 1.9×3.3 | 1,000 | 16 |
0.5 | 7/0.3 x1P □-6FGB-◇-IS |
2 | 7/0.3 | 0.9 | 0.25 | 1.4 | 1.4×2.8 | 0.3 | 0.25 | – | 2.5×3.9 | 1,000 | 27 |
0.5 | 7/0.3 x1P □-6FGB-◇-SOS |
3 | 7/0.3 | 0.9 | 0.25 | 1.4 | 1.4×2.8 | – | 0.25 | 0.3 | 2.5×3.9 | 1,000 | 27 |
0.5 | 20/0.18 x1P □-6FGB-◇ |
1 | 20/0.18 | 1.0 | 0.25 | 1.5 | 1.5×3.0 | – | 0.25 | – | 2.0×3.5 | 1,000 | 18 |
0.5 | 20/0.18 x1P □-6FGB-◇-IS |
2 | 20/0.18 | 1.0 | 0.25 | 1.5 | 1.5×3.0 | 0.3 | 0.25 | – | 2.6×4.1 | 1,000 | 31 |
0.5 | 20/0.18 x1P □-6FGB-◇-SOS |
3 | 20/0.18 | 1.0 | 0.25 | 1.5 | 1.5×3.0 | – | 0.25 | 0.3 | 2.6×4.1 | 1,000 | 31 |
0.75 | 30/0.18 x1P □-6FGB-◇ |
1 | 30/0.18 | 1.2 | 0.25 | 1.7 | 1.7×3.4 | – | 0.3 | – | 2.3×4.0 | 1,000 | 25 |
0.75 | 30/0.18 x1P □-6FGB-◇-IS |
2 | 30/0.18 | 1.2 | 0.25 | 1.7 | 1.7×3.4 | 0.3 | 0.3 | – | 2.9×4.6 | 1,000 | 40 |
0.75 | 30/0.18 x1P □-6FGB-◇-SOS |
3 | 30/0.18 | 1.2 | 0.25 | 1.7 | 1.7×3.4 | – | 0.3 | 0.3 | 2.9×4.6 | 1,000 | 40 |
1.25 | 7/0.45 x1P □-6FGB-◇ |
1 | 7/0.45 | 1.35 | 0.3 | 1.95 | 1.95×3.9 | – | 0.3 | – | 2.6×4.5 | 1,000 | 33 |
1.25 | 7/0.45 x1P □-6FGB-◇-IS |
2 | 7/0.45 | 1.35 | 0.3 | 1.95 | 1.95×3.9 | 0.3 | 0.3 | – | 3.2×5.1 | 1,000 | 49 |
1.25 | 7/0.45 x1P □-6FGB-◇-SOS |
3 | 7/0.45 | 1.35 | 0.3 | 1.95 | 1.95×3.9 | – | 0.3 | 0.3 | 3.2×5.1 | 1,000 | 49 |
1.3 | 4/0.65 x1P □-6FGB-◇ |
1 | 4/0.65 | 1.57 | 0.3 | 2.17 | 2.17×4.34 | – | 0.3 | – | 2.8×4.9 | 1,000 | 43 |
1.3 | 4/0.65 x1P □-6FGB-◇-IS |
2 | 4/0.65 | 1.57 | 0.3 | 2.17 | 2.17×4.34 | 0.3 | 0.3 | – | 3.4×5.5 | 1,000 | 59 |
1.3 | 4/0.65 x1P □-6FGB-◇-SOS |
3 | 4/0.65 | 1.57 | 0.3 | 2.17 | 2.17×4.34 | – | 0.3 | 0.3 | 3.4×5.5 | 1,000 | 60 |
2.3 | 7/0.65 x1P □-6FGB-◇ |
1 | 7/0.65 | 1.95 | 0.3 | 2.55 | 2.55×5.1 | – | 0.3 | – | 3.2×5.7 | 1,000 | 63 |
2.3 | 7/0.65 x1P □-6FGB-◇-IS |
2 | 7/0.65 | 1.95 | 0.3 | 2.55 | 2.55×5.1 | 0.3 | 0.3 | – | 3.8×6.3 | 1,000 | 81 |
2.3 | 7/0.65 x1P □-6FGB-◇-SOS |
3 | 7/0.65 | 1.95 | 0.3 | 2.55 | 2.55×5.1 | – | 0.3 | 0.3 | 3.8×6.3 | 1,000 | 82 |
When placing an order, please replace each of the □ symbols with the type and tolerance class of the appropriate extension and compensating cable for thermocouples (see Table 1), and each of the ◇ symbols with its identification code (see Table 2).
In addition to paired cables, we can make multi-pair cables. Please consult us.
The estimated weights represent calculated values for reference purposes, which do not include the weight of the drum.
*Please feel free to contact our Sales Department for custom-made products not listed above.