Duplex Insulated Ceramic Braided Thermocouple Wire
We provide flat duplex insulated thermocouple wire consisting of a pair of conductors individually ceramic-yarn insulated, and then ceramic-yarn sheathed.


Lineup
Type | Conductor | Insulation | Standard | Max length | Estimated weight |
---|---|---|---|---|---|
Outside diameter | Outside diameter | Outside diameter | |||
mm | mm | mm | m | kg/km | |
0.32 x1P K-CERAC | 0.32 | 0.9 | 1.6 x 2.4 | 100 | 7 |
0.65 x1P K-CERAC | 0.65 | 1.35 | 2.2 x 3.3 | 100 | 16 |
1.0 x1P K-CERAC | 1.0 | 1.8 | 2.6 x 4.2 | 100 | 28 |
0.32 x1P K-CF | 0.32 | 0.9 | 1.6 x 2.4 | 100 | 7 |
0.65 x1P K-CF | 0.65 | 1.35 | 2.2 x 3.3 | 100 | 16 |
1.0 x1P K-CF | 1.0 | 1.8 | 2.6 x 4.2 | 100 | 28 |
*Operating Temperatures
Conductor diameter | Normal-use temperature limit | Overheating temperature limit |
---|---|---|
mm | ℃ | ℃ |
0.32 | 400 | 500 |
0.65 | 650 | 850 |
1.0 | 750 | 950 |
If required, wire can be protectively braided (to protect the wire surface from damage).
Protective braid type: SOS – Protective stainless-wire braid
We can also make products of Tolerance Class 1.
Please feel free to contact us for custom-made products not listed above.
K-CF series products use no sizing agent for ceramic yarns. Although not as mechanically strong as the K-CERAC series products, K-CF series products undergo almost no outgassing from the sizing agent and suffer almost no loss in insulating performance when the sizing agent is decomposed by high temperatures.