Ninomiya Electric Wire Ninomiya Electric Wire Co.,Ltd.60th Anniversary

HRWHeat-Resistant Wires

Glass-yarn braided Nickel-conductor Wire: NI-GB

Compliant with RoHS2
Max. operating temp:220℃

NI-GB is a heat-resistant wire, the conductors of which are made of nickel wire that is highly resistant to heat as well as corrosion and covered with glass fiber. A silicone coating, which excels in insulating characteristics, is applied to the insulation of NI-GB. NI-GB is manufactured according to the NINOMIYA Standards.

Applications

NI-GB is used for applications such as the lead wire in an electric heater, which must be highly resistant to heat as well as corrosion, and wire in high-temperature equipment.

Lineup

Nominal cross-sectional area
m㎡
Conductor Served glass yarn thickness
mm
Braid thickness
mm
Standard overall diameter
mm
Conductor resistance
(20℃, standard)
Ω/km
Insulation resistance
(20℃, minimum)
MΩ・km
Test voltage
(AC, 1 min.)
V
Estimated weight
kg/km
Composition
Pcs/mm
Outside diameter
mm
0.5 20/0.18 0.9 0.15 0.3 1.9 192 1.0 1000 10
0.75 30/0.18 1.1 0.15 0.3 2.1 128 1.0 1000 13
1.25 50/0.18 1.5 0.15 0.35 2.5 77.0 1.0 1000 19
2.0 37/0.26 1.8 0.15 0.35 2.8 49.8 1.0 1000 26
3.5 66/0.26 2.4 0.15 0.35 3.4 27.9 1.0 1000 44
5.5 35/0.45 3.1 0.15 0.35 4.1 17.6 1.0 1000 63
8 50/0.45 3.7 0.6 4.9 12.3 1.0 1000 88
14 88/0.45 4.9 0.6 6.1 7.00 1.0 1000 146
22 7/20/0.45 7.0 0.6 8.2 4.49 1.0 1000 235
38 7/34/0.45 9.1 0.6 10.3 2.64 1.0 1000 390

*Since NI-GB series products have hygroscopicity, their insulating characteristics differ depending on the atmosphere in which each of them is routed. Therefore, avoid using NI-GB series products in humid or wet places. Please feel free to contact our Sales Department for custom-made products not listed above.

List of allowable current values

Size Ambient temperature
90℃ 100℃ 110℃ 120℃ 130℃ 140℃ 150℃ 160℃ 170℃ 180℃ 190℃ 200℃ 210℃
0.5SQ 8.5 8.2 7.8 7.5 7.1 6.7 6.3 5.9 5.3 4.8 4.0 3.3 2.2
0.75SQ 10.8 10.4 10.0 9.5 9.1 8.6 8.0 7.4 6.7 6.1 5.2 4.1 2.9
1.25SQ 15.1 14.5 13.9 13.3 12.7 12.0 11.3 10.4 9.6 8.5 7.2 6.0 4.1
2SQ 19.5 18.7 18.1 17.2 16.5 15.6 14.6 13.5 12.4 11.1 9.4 7.7 5.0
3.5SQ 28.0 27.0 25.9 24.8 23.6 22.4 20.9 19.5 17.7 16.0 13.8 11.1 7.5
5.5SQ 37.9 36.4 35.2 33.6 31.9 30.1 28.2 26.2 24.0 21.5 18.8 14.9 10.5
8SQ 47.9 46.3 44.5 42.7 40.8 38.5 36.4 33.7 30.7 27.5 23.8 19.4 13.7
14SQ 69.4 66.8 64.1 61.9 58.9 55.8 52.6 48.4 44.6 40.4 34.7 27.9 18.0
22SQ 97.6 94.3 91.0 87.5 83.8 79.0 75.0 69.5 63.7 57.3 50.0 39.5 27.9
38SQ 138 133 128 123 118 112 105 98.7 90.1 80.6 69.8 57.0 40.3

*The above allowable current values are the values calculated based on the assumption that the products are used in a normal open atmosphere.
Please use NI-GB series products with a safety current that ensures safe operation.

*The above allowable current values of NI-GB series products are the reference values calculated based on our demonstration experiments.

*NI-GB series products are manufactured according to the Standards of Ninomiya Electric Wire Co., Ltd.