Polyimide-tape wrapped Glass-yarn braided Nickel-conductor Wire: KPGB
Max. operating temp:220℃
Rated voltage:600V
KPGB is a heat-resistant wire, the conductors of which are made of nickel wire that is highly resistant to heat as well as corrosion and wrapped in polyimide tape coated with glass fiber. A silicone coating, which excels in insulating characteristics, is applied to the insulation of KPGB. The polyimide tape which wraps around the conductor makes KPGB superior in insulating characteristics to NI-GB. KPGB is manufactured according to the NINOMIYA Standards.
Applications
KPGB is used for applications such as the lead wire in an electric heater, which must be highly resistant to heat as well as corrosion, and wire in high-temperature equipment.
Lineup
Nominal cross-sectional area m㎡ |
Conductor | Taping thickness mm |
Served glass yarn thickness mm |
Braid thickness mm |
Standard overall diameter mm |
Conductor resistance (20℃, standard) Ω/km |
Insulation resistance (20℃, minimum) MΩ・km |
Test voltage (AC, 1 min.) V |
Estimated weight kg/km |
|
---|---|---|---|---|---|---|---|---|---|---|
Composition Pcs/mm |
Outside diameter mm |
|||||||||
0.5 | 20/0.18 | 0.9 | 0.025 | 0.15 | 0.3 | 2.0 | 192 | 10 | 2000 | 9 |
0.75 | 30/0.18 | 1.1 | 0.025 | 0.15 | 0.3 | 2.2 | 128 | 10 | 2000 | 12 |
1.25 | 50/0.18 | 1.5 | 0.025 | 0.15 | 0.35 | 2.6 | 77.0 | 10 | 2000 | 17 |
2.0 | 37/0.26 | 1.8 | 0.025 | 0.15 | 0.35 | 2.9 | 49.8 | 10 | 2000 | 24 |
3.5 | 66/0.26 | 2.4 | 0.025 | 0.15 | 0.35 | 3.5 | 27.9 | 10 | 2000 | 41 |
5.5 | 35/0.45 | 3.1 | 0.025 | 0.15 | 0.35 | 4.2 | 17.6 | 10 | 2000 | 65 |
8 | 50/0.45 | 3.7 | 0.025 | – | 0.6 | 5.0 | 12.3 | 10 | 2000 | 95 |
14 | 88/0.45 | 4.9 | 0.025 | – | 0.6 | 6.2 | 7.00 | 10 | 2000 | 155 |
22 | 7/20/0.45 | 7.0 | 0.025 | – | 0.6 | 8.3 | 4.49 | 10 | 2000 | 245 |
38 | 7/34/0.45 | 9.1 | 0.025 | – | 0.6 | 10.4 | 2.64 | 10 | 2000 | 405 |
*Since KPGB series products have hygroscopicity, their insulating characteristics differ depending on the atmosphere in which each of them is routed. Therefore, avoid using the KPGB series products in humid or wet places. Please feel free to contact our Sales Department for custom-made products not listed above.
List of allowable current values
Size | Ambient temperature | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
90℃ | 100℃ | 110℃ | 120℃ | 130℃ | 140℃ | 150℃ | 160℃ | 170℃ | 180℃ | 190℃ | 200℃ | 210℃ | |
0.5SQ | 8.5 | 8.2 | 7.8 | 7.5 | 7.1 | 6.7 | 6.3 | 5.9 | 5.3 | 4.8 | 4.0 | 3.3 | 2.2 |
0.75SQ | 10.8 | 10.4 | 10.0 | 9.5 | 9.1 | 8.6 | 8.0 | 7.4 | 6.7 | 6.1 | 5.2 | 4.1 | 2.9 |
1.25SQ | 15.1 | 14.5 | 13.9 | 13.3 | 12.7 | 12.0 | 11.3 | 10.4 | 9.6 | 8.5 | 7.2 | 6.0 | 4.1 |
2SQ | 19.5 | 18.7 | 18.1 | 17.2 | 16.5 | 15.6 | 14.6 | 13.5 | 12.4 | 11.1 | 9.4 | 7.7 | 5.0 |
3.5SQ | 28.0 | 27.0 | 25.9 | 24.8 | 23.6 | 22.4 | 20.9 | 19.5 | 17.7 | 16.0 | 13.8 | 11.1 | 7.5 |
5.5SQ | 37.9 | 36.4 | 35.2 | 33.6 | 31.9 | 30.1 | 28.2 | 26.2 | 24.0 | 21.5 | 18.8 | 14.9 | 10.5 |
8SQ | 47.9 | 46.3 | 44.5 | 42.7 | 40.8 | 38.5 | 36.4 | 33.7 | 30.7 | 27.5 | 23.8 | 19.4 | 13.7 |
14SQ | 69.4 | 66.8 | 64.1 | 61.9 | 58.9 | 55.8 | 52.6 | 48.4 | 44.6 | 40.4 | 34.7 | 27.9 | 18.0 |
22SQ | 97.6 | 94.3 | 91.0 | 87.5 | 83.8 | 79.0 | 75.0 | 69.5 | 63.7 | 57.3 | 50.0 | 39.5 | 27.9 |
38SQ | 138 | 133 | 128 | 123 | 118 | 112 | 105 | 98.7 | 90.1 | 80.6 | 69.8 | 57.0 | 40.3 |
*The above allowable current values are the values calculated based on the assumption that the products are used in a normal open atmosphere.
Please use KPGB series products with the safety current that ensures safe operation.
*The above allowable current values of KPGB series products are the reference values calculated based on our demonstration experiments.
*KPGB series products are manufactured according to the Standards of Ninomiya Electric Wire Co., Ltd.