Ninomiya Electric Wire Ninomiya Electric Wire Co.,Ltd.60th Anniversary

HRWHeat-Resistant Wires

Silica-glass-yarn braided Nickel-clad-copper-conductor Wire: TN430

Compliant with RoHS2
Max. operating temp:400℃

TN430 is a super heat-resistant wire, the conductors of which are heat-resistant and corrosion-resistant as well as flexible nickel-clad-copper-conductor wire wrapped in glass-mica-polyimide-composite tape coated with silica-glass fiber. Polyimide coating, which is brownish-red and excels in insulating characteristics, is applied to the insulation of TN430. TN430 is manufactured according to the NINOMIYA Standards.

Features of nickel-clad-copper-conductor wire

  • The conductor resistance of nickel-clad-copper-conductor wire is about a quarter (1/4) of that of nickel-conductor wire; therefore the former can be thinner in diameter and lighter than the latter while the allowable current value of the former is the same as that of the latter.
  • Since nickel-clad-copper-conductor wire is more flexible than nickel-conductor wire, it can be easily processed and routed.
  • The nickel plate is 20 to 30 times as thick as conventional nickel plate (1 to 5μm). Note that the area ratio between nickel and copper is about 28:72.
  • Since the surface of nickel-clad-copper-conductor wire is nickel, it is more corrosion-resistant than copper wire.
  • Its electric conductivity changes over time in high temperature use. However, about 60% of the electric conductivity is maintained even after the nickel-clad-copper-conductor wire is used at a temperature of 400℃ for three consecutive years.

Applications

TN430 is used for applications such as the lead wire in an electric heater, which must be highly resistant to heat as well as corrosion, and wire in high-temperature equipment.

Lineup

Nominal cross-sectional area
m㎡
Conductor Taping thickness
mm
Braid thickness
mm
Standard overall diameter
mm
Conductor resistance
(20℃, standard)
Ω/km
Insulation resistance
(20℃, minimum)
MΩ・km
Test voltage
(AC, 1 min.)
V
Estimated weight
kg/km
Composition
Pcs/mm
Outside diameter
mm
0.75 30/0.18 1.2 0.25 0.6 2.9 29.7 10 1500 14
1.25 50/0.18 1.5 0.25 0.7 3.4 17.8 10 1500 22
2.0 37/0.26 1.8 0.25 0.7 3.7 11.5 10 1500 31
3.5 66/0.26 2.6 0.25 0.7 4.5 6.46 10 1500 48
5.5 35/0.45 3.1 0.25 0.8 5.2 4.07 10 1500 75
8 50/0.45 3.7 0.25 0.8 5.8 2.85 10 1500 95
14 88/0.45 4.9 0.25 0.8 7.0 1.62 10 1500 160
22 7/20/0.45 7.0 0.25 0.8 9.1 1.04 10 1500 240
38 7/34/0.45 9.1 0.25 0.8 11.2 0.610 10 1500 400

*Since TN430 series products have hygroscopicity, their insulating characteristics differ depending on the atmosphere in which each of them is routed. Therefore, avoid using TN430 series products in humid or wet places. Please feel free to contact our Sales Department for custom-made products not listed above.

List of allowable current values

Size Ambient temperature
140℃ 150℃ 160℃ 170℃ 180℃ 190℃ 200℃ 210℃ 220℃ 230℃ 240℃ 250℃ 260℃
0.75SQ 35.5 35.0 34.5 34.0 33.4 32.8 32.2 31.6 30.9 30.2 29.5 28.7 27.9
1.25SQ 49.0 48.4 47.7 47.0 46.2 45.4 44.6 43.7 42.8 41.9 40.9 39.8 38.7
2SQ 63.5 62.7 61.8 60.9 59.9 58.9 57.9 56.7 55.6 54.3 53.1 51.7 50.3
3.5SQ 94.1 92.9 91.6 90.3 88.9 87.4 85..8 84.2 82.6 80.8 78.9 76.9 74.8
5.5SQ 123 121 119 118 116 114 112 110 108 105 103 100 98.0
8SQ 154 453 150 148 146 144 141 139 136 133 130 127 123
14SQ 224 221 218 215 212 208 205 201 197 193 189 184 179
22SQ 319 315 311 307 302 297 293 287 282 276 270 263 256
38SQ 454 449 443 437 431 424 417 410 402 394 385 375 365
Size Ambient temperature
270℃ 280℃ 290℃ 300℃ 310℃ 320℃ 330℃ 340℃ 350℃ 360℃ 370℃ 380℃ 390℃
0.75SQ 27.1 26.2 25.2 24.1 23.1 21.9 20.6 19.2 17.5 15.8 13.7 11.2 7.9
1.25SQ 37.5 36.3 34.9 33.6 32.0 30.4 28.6 26.6 24.4 21.9 19.1 15.5 10.9
2SQ 48.8 47.1 45.4 43.6 41.6 39.5 37.1 34.5 31.7 28.5 24.9 20.2 14.2
3.5SQ 72.5 70.2 67.6 64.9 62.0 58.8 554 51.6 47.4 42.7 37.1 30.2 21.5
5.5SQ 95.1 92.0 88.7 85.2 81.4 77.2 72.6 67.7 62.1 55.8 48.7 39.6 28.3
8SQ 119 116 111 107 102 97.4 91.9 85.5 786 70.7 61.4 50.4 35.6
14SQ 174 168 162 156 149 141 133 124 114 102 89.6 73.6 52.1
22SQ 249 241 232 223 213 203 191 178 164 147 128 105 73.8
38SQ 355 344 332 318 305 289 272 254 234 210 183 150 106

*The above allowable current values are the values calculated based on the assumption that the products are used in a normal open atmosphere.
Please use TN430 series products with a safety current that ensures safe operation.

*The above allowable current values of TN430 series products are the reference values calculated based on our demonstration experiments.

*TN430 series products are manufactured according to the Standards of Ninomiya Electric Wire Co., Ltd.